LAB / SM Series

  • Extremely compact 100kHz Mos design
  • Power factory correction as standard
  • Analogue and computer interfaces
  • CC/CV modes of operation
  • Current and voltage presets

The LAB/SM series of Laboratory DC Sources provides power outputs of up to 12kW. A wide array of voltage and current ranges are available at each power rating. Constant voltage and constant current operating modes are provided. PFC of 0.98 is standard across the entire range.

Standard features include preset voltage and current outputs, adjustable over voltage protection, remote sense, stand by and thermal overload protection. The combination of automatic ranging with automatic power control often saves the need to acquire a second unit.

The LAB/SM series of power supplies may be remotely controlled using a number of optional analogue and/or computer interfaces. LabVIEW® drivers are also available for GPIB computer control and system integration.

The power supplies are suitable for a wide variety of applications including automotive, general laboratory applications, battery charging and automatic test systems. Exceptional flexibility of design allows virtually any output configuration to be supplied. Please contact our sales office if your requirements are not covered by the standard units.
information request...
Replacements for Obsolete AP Series
Recommended replacements for the obsolete Wayne Kerr/Farnell AP series of power supplies are available and are highlighted in the following table.

Power (W)

Output Voltage (VDC)

Output Current (IDC)

Height (U)

Part No.

500 0 - 15 0 - 33 2 ETLAB/SM0515
0 - 35 0 - 14 ETLAB/SM0535
0 - 70 0 - 8 ETLAB/SM0570
0 - 150 0 - 3.5 ETLAB/SM05150
500 0 - 20 0 - 80 2 ETLAB/SM0520/CP/AP/2U
0 - 70 0 - 30  ETLAB/SM0570/CP/AP/2U
0 - 400 0 - 5 4 ETLAB/SM05400/CP/AP/4U
750 0 - 15 0 - 50 2 ETLAB/SM0715
0 - 35 0 - 25 ETLAB/SM0735
0 - 70 0 - 12 ETLAB/SM0770
0 - 150 0 - 5 ETLAB/SM07150
800 0 - 500 0 - 1.6 1 ETLAB/SM1500
1000 0 - 5 0 - 150 1 ETLAB/SM105
0 - 8 0 - 125 ETLAB/SM108
0 - 20 0 - 50 ETLAB/SM120
0 - 35 0 - 35 ETLAB/SM135
0 - 45 0 - 30 ETLAB/SM145
0 - 70 0 - 20 ETLAB/SM170
0 - 150 0 - 10 ETLAB/SM1150
0 - 300 0 - 6 ETLAB/SM1300
1000 0 - 30 0 - 80 2 ETLAB/SM130/CP/AP/2U
0 - 60 0 - 50 ETLAB/SM160/CP/AP/2U
0 - 100 0 - 30 ETLAB/SM1100/CP/AP/2U
1200 0 - 600 0 - 2 2 ETLAB/SM1600
2000 0 - 20 0 - 100 2 ETLAB/SM220
0 - 35 0 - 70 ETLAB/SM235
0 - 45 0 - 50 ETLAB/SM245
0 - 70 0 - 35 ETLAB/SM270
0 - 150 0 - 15 ETLAB/SM2150
0 - 300 0 - 8 ETLAB/SM2300
0 - 600 0 - 4 ETLAB/SM2600
3000 0 - 20 0 - 150 4 ETLAB/SM320
0 - 35 0 - 100 ETLAB/SM335
0 - 45 0 - 75 ETLAB/SM345
0 - 70 0 - 50 ETLAB/SM370
0 - 150 0 - 20 ETLAB/SM3150
0 - 300 0 - 12 ETLAB/SM3300
3000 0 - 30 0 - 250 6 ETLAB/SM330/CP/AP/6U
0 - 60 0 - 150 ETLAB/SM360/CP/AP/6U
0 - 100 0 - 90 ETLAB/SM3100/CP/AP/6U
4000 0 - 20 0 - 200 4 ETLAB/SM420
0 - 35 0 - 140 ETLAB/SM435
0 - 45 0 - 100 ETLAB/SM445
0 - 70 0 - 70 ETLAB/SM470
0 - 150 0 - 30 ETLAB/SM4150
0 - 300 0 - 16 ETLAB/SM4300
6000 0 - 20 0 - 300 6 ETLAB/SM620
0 - 35 0 - 210 ETLAB/SM635
0 - 45 0 - 150 ETLAB/SM645
0 - 70 0 - 105 ETLAB/SM670
0 - 150 0 - 45 ETLAB/SM6150
0 - 300 0 - 24 ETLAB/SM6300
8000 0 - 20 0 - 400 8 ETLAB/SM820
0 - 35 0 - 280 ETLAB/SM835
0 - 45 0 - 200 ETLAB/SM845
0 - 70 0 - 140 ETLAB/SM870
0 - 150 0 - 60 ETLAB/SM8150
0 - 300 0 - 32 ETLAB/SM8300
10000 0 - 10 0 - 1000 10 ETLAB/SM1010
0 - 20 0 - 500 ETLAB/SM1020
0 - 35 0 - 350 ETLAB/SM1035
0 - 45 0 - 250 ETLAB/SM1045
0 - 70 0 - 175 ETLAB/SM1070
0 - 150 0 - 75 ETLAB/SM10150
0 - 300 0 - 40 ETLAB/SM10300
12000 0 - 20 0 - 600 12 ETLAB/SM1220
0 - 60 0 - 420 ETLAB/SM1235
0 - 45 0 - 300 ETLAB/SM1245
0 - 70 0 - 210 ETLAB/SM1270
0 - 150 0 - 90 ETLAB/SM12150
0 - 300 0 - 48 ETLAB/SM12300

Options

Option

Description

/ATE No front panel control or display. Analogue interface fitted as standard.
/AI 5 0 ­ 5V analogue interface for control and measurement
/AI 10 0 ­ 10V analogue interface for control and measurement
/ATI 5 Isolated 0 ­ 5V analogue interface for control and measurement
/ATI 10 Isolated 0 ­ 10V analogue interface for control and measurement
/LT IEEE 488.2 interface with both listener and talker functions.
/LTRS RS 232 interface with listener and talker functions.
/LT + LTRS IEEE 488.2  and RS232 interface with both listener and talker functions.
/LTRS485 RS485 interface with listener and talker functions
/CAN CAN interface with listener and talker functions
/USB USB interface with both listener and talker functions
/WIPC 90-264Vac input with active PFC (only available for 500W/750W units)
/PFCX 185 - 264Vac input with active PFC (only available for 800W & 1 - 4kW
/PFCZ 90 - 135Vac input with active PFC (only available for 800W & 1 - 4kW)
/3P 3 * 400VAC input for 2kW to 12kW units
/3P + N 3 * 400VAC input + neutral (standard for units 4 - 12kW)
/R Constant resistance mode (on units => 800W)
/P Constant power mode (on units => 800W)
/KFZ12 Output follows a 12Vdc automotive cranking curve
/KFZ24 Output follows a 24Vdc automotive cranking curve
/KFZXX Output follows a user specified curve
/OCP Adjustable over current protection in addition to the standard current limit
/AF Power output on the front panel (satandard 500W/750W)
/AR Power output on the rear panel (standard => 1kW)

Technical Data

Input voltage (500W - 3kW Output) 230VAC ±10%
Input voltage (Output => 4kW) 3 x 400VAC ±10%
Input frequency 47 - 63 Hz
Insulation (input/output) 3000 VAC
Power Factor Correction 0.98
Typical Efficiency 85%
Voltage Regulation ±0.05% + 2mV
Current Regulation ±0.1% + 2mA
Response Time (10% - 90%) <0.5mS
Over Voltage Protection 0 to 110% Vmax
Ripple <0.2% RMS
Stability 0.05%
Operating temperature 0 - 50° C
Storage temperature -45° C to +85° C
Temperature coefficient 0.02% per °C
Derating 50°C - 70°C -2% per °C
Harmonics EN61000-3-2 A14
Safety EN60950
Emission EN61000-6-4
Immunity EN61000-6-2
Protection OC / OV / OT / OP
Remote Sense (<35V) 2Vmax
Remote Sense (>35V) 5Vmax
Isolation Class 1
Computer interface resolution 12 bit
Cooling (500W & 750W) Front to back
Cooling (1kW) Back to back
Cooling (2 - 12kW) Front to back
Vibration 10 - 55Hz / 1min/ 2G XYZ
Shock Less than 20G
Case Sizes 500W & 750W (W x H x D) 0.5 * 19" x 2U x 360mm
Case Sizes 1kW - 12kW (W x H x D) 19" x H x 434.5mm

Information Request


  Enter the power supply part number or full details of your application requirements.

If you have a power supply you wish to replace then please give the manufacturer  model number and overall specification if available.

  Quotation Request
 
 


Product Comparison
Impedance Analysis
LCR
Wound Components
Telecommunication
Impulse/Surge Test
Cable Harness
Modulation Analysis
DC Power Supplies
Accessories

Home | Up | Products | Contact Us | Support | Search

Registered Office: Wayne Kerr Electronics, 5th Floor, 7-10 Chandos Street, Cavendish Square, London.
Registered in England No. 4198428. Copyright © 2008 Wayne Kerr Electronics Ltd