High Power Sources (UK Only)

|
|
|
|
LAB / TC Series - 10kW to 32kW |
|
|
|
 |
- Ultra compact 3U design
- Simple front panel operation
- Adjustable internal resistance
- Optional Computer Interfaces
-
CV, CC, CP and CR modes
- Worldwide input options
|
|
The LAB/HP supplies up to 15kW of power in just a 3U
high case.
The active parallel mode enables up to 6 identical units to be operated
together providing an output of up to 90kW. The high
visibility LED display and 10 turn potentiometers allow for
straightforward front panel operation. Voltage and current values can be
preset and read prior to releasing the output. Fused output terminals on the front panel are useful for low power operation enabling up to 10A to be taken.
RS232 and 0 - 5Vdc analogue interfaces are built in as standard.
0 - 10Vdc, RS485, GPIB, USB and CAN interfaces are optionally available. LabView®
drivers and ATE options are offered for system integration.
The LAB/HPs compact design delivers high efficiencies of up to 94%. Adjustable
internal resistance and optional car starting curves make this range ideal for automotive
simulation as well as general laboratory and production work.
The flexibility of design enables non-standard
outputs and customer specific options to be provided ensuring the LAB/HP
is suitable for the widest variety of applications. |
| |
Information Request.. |
Power (W) |
Output Voltage (VDC) |
Output Current (IDC) |
Height (U) |
Part No. |
|
5kW |
0 - 40 |
0 - 125 |
3 |
ETLAB/HP 540 |
|
0 - 80 |
0 - 65 |
ETLAB/HP 580 |
|
0 - 100 |
0 - 50 |
ETLAB/HP 5100 |
|
0 - 150 |
0 - 35 |
ETLAB/HP 5150 |
|
0 - 300 |
0 - 17 |
ETLAB/HP 5300 |
|
0 - 600 |
0 - 8.5 |
ETLAB/HP 5600 |
|
10kW |
0 - 40 |
0 - 250 |
ETLAB/HP 1040 |
|
0 - 80 |
0 - 130 |
ETLAB/HP 1080 |
|
0 - 100 |
0 - 100 |
ETLAB/HP 10100 |
|
0 - 150 |
0 - 70 |
ETLAB/HP 10150 |
|
0 - 300 |
0 - 34 |
ETLAB/HP 10300 |
|
0 - 600 |
0 - 17 |
ETLAB/HP 10600 |
|
15kW |
0 - 40 |
0 - 375 |
ETLAB/HP 1540 |
|
0 - 80 |
0 - 195 |
ETLAB/HP 1580 |
|
0 - 100 |
0 - 150 |
ETLAB/HP 15100 |
|
0 - 150 |
0 - 100 |
ETLAB/HP 15150 |
|
0 - 300 |
0 - 50 |
ETLAB/HP 15300 |
|
0 - 600 |
0 - 25 |
ETLAB/HP 15600 |
|
| |
Options
|
Option
|
Description
|
|
/3P208 |
|
3 Phase input of 3 * 208 (187 - 229Vac), 50/60Hz |
|
/3P400 |
|
3 Phase input of 3 * 400 (360 - 440Vac), 50/60Hz |
|
/3P480 |
|
3 Phase input of 3 * 480 (432 - 528Vac), 50/60Hz |
|
/ATE |
|
No front panel control or display. Analogue interface
provided as standard |
|
/AI-10 |
|
0 - 10V Analogue interface for all control and
measurement functions |
|
/ATI-5 |
|
Isolated 0 - 5V Analogue interface for all control
and measurement functions |
|
/ATI-10 |
|
Isolated 0 - 10V Analogue interface for all control
and measurement functions |
|
/LF |
|
Improved output rise time to 3µs/A
(ripple and noise doubles with option /LF) |
|
/OCP |
|
Adjustable over current protection in addition to the
standard current limit |
|
/USB |
|
USB Interface with both listener and talker functions
(replaces RS232 port) |
|
/LT |
|
IEEE 488.2 Interface with both listener and talker
functions (12 bit) |
|
/RS485 |
|
RS485 Interface with both listener and talker
functions (12 bit) |
|
/CAN |
|
CAN Interface with both listener and talker functions
(12 bit) |
|
/KFZ12 |
|
Output follows a 12Vdc automotive cranking curve |
|
/KFZ24 |
|
Output follows a 24dc automotive cranking curve |
|
/KFZXX |
|
Output follows a user specific curve |
|
|
Technical Data
|
|
Input voltage |
see options table above |
|
Input frequency |
47 - 63 Hz |
|
Harmonics |
EN61000-3-2 A14 |
|
Insulation (Input /Output) |
3000 Vac |
|
Isolation class |
1 |
|
Safety |
EN60950 |
|
Emissions |
EN61000-6-4 |
|
Immunity |
EN61000-6-2 |
|
Voltage Regulation |
±0.05% + 2mV |
|
Current Regulation |
±0.1% + 2mA |
|
Response time (10% - 90%) |
<0.5ms (typ) |
|
Ripple and Noise |
<0.025% Vmax |
|
Stability |
0.05% Vmax |
|
Over Voltage Protection |
0 - 110% Vmax |
|
Remote Sense Capability (<35V) |
2V |
|
Remote Sense Capability (>35V) |
5V |
|
Protections |
OC / OV / OT /OP |
|
Built in Analogue Interface |
0 - 5Vdc (Option 0 -10Vdc) |
|
Built in RS232 Interface |
12 Bit |
|
Adjustable Internal Resistance |
0 to 15Ω |
|
Operating Temperature |
0 to +50°C |
|
Storage Temperature |
-45°C to +85°C |
|
Derating 50°C - 70°C |
-2% per °C |
|
Operating/Storage Humidity |
0 to 95% (non condensing) |
|
Cooling |
Forced air |
|
Air Flow |
Front to back |
|
Vibration |
10 - 55Hz / 1min/2G XYZ |
|
Shock |
Less than 20G |
|
Case sizes |
19" x 3U x 600mm |
|
|
|
 |
- Unique full digital regulation
- Adjustable PID parameters
- Adjustable internal resistance
- Parallel, series and multi-load operation
- Up to 1kVdc and over 2 Megawatts
- Extremely compact, 32kW = 9U high
- CP as well as CC/CV operating modes
- Stand alone software package
|
|
The LAB/TC range is a highly advanced series of
programmable DC power supplies. The units are built into 19" racks and
are available in 10kW, 16kW, 20kW, and 32kW modules. Constant voltage,
current and power operating modes are provided. The internal resistance
can be adjusted making the LAB/TC range ideal for battery simulation.
Remote sense is provided to compensate for the voltage drop in the load
lines.
These DC sources can be fitted with front panel control and an LCD
display. Analogue and RS232 interfaces are provided as standard. An easy
to use, stand alone software program is also included. GPIB, CAN, RS422
and USB are optionally available. LabView®
and C/C++ are supported if required.
All regulation, monitoring and communication tasks are conducted by
high performance micro-controllers and digital signal processors. This
provides exceptional accuracy, reproducibility and long term stability.
The PID parameters of the power supply's controllers can be configured
to the needs of particular loads.
A built in function generator option is offered with application
area programming allowing the output to properly simulate actual
devices such as solar panels, rotating generators, power stacks and
fuel cells. Bipolar and bidirectional functionality with mains
recycling options can also be specified.
By employing the latest IGBT technology and innovative nano-crystalline
transformers an excellent efficiency of up to 95% is achieved. |
| |
Information Request... |
Power (W) |
Output Voltage (VDC) |
Output Current (IDC) |
Height (U) |
Part No. |
|
10kW |
0 - 52 |
0 - 250 |
6 |
ETLAB/TC 10/52 |
|
0 - 60 |
0 - 193 |
ETLAB/TC 10/60 |
|
0 - 65 |
0 - 193 |
ETLAB/TC 10/65 |
|
0 - 100 |
0 - 125 |
ETLAB/TC 10/100 |
|
0 - 200 |
0 - 63 |
ETLAB/TC 10/200 |
|
0 - 400 |
0 - 31 |
ETLAB/TC 10/400 |
|
0 - 500 |
0 - 25 |
ETLAB/TC 10/500 |
|
0 - 600 |
0 - 20 |
ETLAB/TC 10/600 |
|
0 - 800 |
0 - 16 |
ETLAB/TC 10/800 |
|
0 - 1000 |
0 - 13 |
ETLAB/TC 10/1000 |
|
16kW |
0 - 52 |
0 - 400* |
6 |
ETLAB/TC 16/52 |
|
0 - 60 |
0 - 308* |
ETLAB/TC 16/60 |
|
0 - 65 |
0 - 308* |
ETLAB/TC 16/65 |
|
0 - 100 |
0 - 200* |
ETLAB/TC 16/100 |
|
0 - 200 |
0 - 100 |
ETLAB/TC 16/200 |
|
0 - 400 |
0 - 50 |
ETLAB/TC 16/400 |
|
0 - 500 |
0 - 40 |
ETLAB/TC 16/500 |
|
0 - 600 |
0 - 32 |
ETLAB/TC 16/600 |
|
0 - 800 |
0 - 25 |
ETLAB/TC 16/800 |
|
0 - 1000 |
0 - 20 |
ETLAB/TC 16/1000 |
|
20kW |
0 - 52 |
0 - 500* |
9 |
ETLAB/TC 20/52 |
|
0 - 60 |
0 - 385* |
ETLAB/TC 20/60 |
|
0 - 65 |
0 - 385 |
ETLAB/TC 20/65 |
|
0 - 100 |
0 - 250 |
ETLAB/TC 20/100 |
|
0 - 200 |
0 - 125 |
ETLAB/TC 20/200 |
|
0 - 400 |
0 - 63 |
ETLAB/TC 20/400 |
|
0 - 500 |
0 - 50 |
ETLAB/TC 20/500 |
|
0 - 600 |
0 - 40 |
ETLAB/TC 20/600 |
|
0 - 800 |
0 - 32 |
ETLAB/TC 20/800 |
|
0 - 1000 |
0 - 25 |
ETLAB/TC 20/1000 |
|
32kW |
0 - 52 |
0 - 700* |
9 |
ETLAB/TC 32/52 |
|
0 - 60 |
0 - 600* |
ETLAB/TC 32/60 |
|
0 - 65 |
0 - 600* |
ETLAB/TC 32/65 |
|
0 - 100 |
0 - 400* |
ETLAB/TC 32/100 |
|
0 - 200 |
0 - 200* |
ETLAB/TC 32/200 |
|
0 - 400 |
0 - 100* |
ETLAB/TC 32/400 |
|
0 - 500 |
0 - 80* |
ETLAB/TC 32/500 |
|
0 - 600 |
0 - 64* |
ETLAB/TC 32/600 |
|
0 - 800 |
0 - 50* |
ETLAB/TC 32/800 |
|
0 - 1000 |
0 - 40* |
ETLAB/TC 32/1000 |
|
|
* These models have ambient temperature restrictions. Please contact
Wayne Kerr Electronics for more information. No current derating if power supply is
specified with the optional liquid cooling. |
Options
|
Option
|
Description
|
|
/HMI |
|
Front panel control and display in English or German
(user switchable) |
|
/RXTS |
|
Extended internal resistance range of 0-12Ω |
|
/LC |
|
Integrated liquid cooling of the power stage |
|
/RCU 19 |
|
Remote control unit built into 19" x 3U x 290mm (WxHxD)
rack |
|
/RCU DT |
|
Remote control unit provided as a desktop unit
measuring 355x100x290mm (WxHxD) |
|
/RS422 |
|
Upgrade of RS232 interface to RS422 standard |
|
/IEEE |
|
Parallel to serial converter to allow GPIB operation
via RS232 interface |
|
/CANCABLE |
|
Connecting cable for multi-unit operation |
|
/CANOPEN |
|
Field BUS interface |
|
/INTERBUS |
|
Field BUS interface |
|
/PROFIBUS |
|
Field BUS interface |
|
/DEVICENET |
|
Field BUS interface |
|
|
Technical Data
|
|
Input voltage |
3 x 360 - 440 VAC |
|
Input frequency |
48 - 62 Hz |
|
Power inlet connection |
3L + PE (no neutral) |
|
Operating modes |
Constant voltage (0 - 100% of Vmax)
Constant current (0 - 100% of Imax)
Constant power (5 - 100% of Pmax) |
|
Insulation resistance range |
0 - 1000mΩ (optional 0 - 12Ω) |
|
Interfaces |
Analogue & RS232 |
|
Remote sense |
10% Vnom |
|
Efficiency |
Up to 95% |
|
Load regulation (CV, CC) |
< ±0.1% |
|
Line regulation (CV, CC) |
< ±0.1% |
|
Response time (10% - 90%) |
< 2mS |
|
Over voltage protection |
0 to 110% of Vmax |
|
Over current protection |
0 to 110% of Imax |
|
Output ripple (300Hz) |
< 0.4% |
|
Output noise (40kHz 1MHz) |
< 0.1V rms |
|
Stability (CV, CC) |
< ±0.05% |
|
Operating Temperature |
5 to 40 °C |
|
Temperature Coefficient (CV) |
0.02% per °C |
|
Temperature Coefficient (CC) |
0.03% per °C |
|
Case sizes |
19" x H x 495mm (10kW & 16kW)